Technical Application Notes
Situation:
A construction material recycling company has a series of 30 conveyors that feed one another in a multi stage process. If one conveyor
stops abruptly, the conveyor feeding it continues, and material piles up rapidly as it has nowhere to go. One by one the conveyors stop
abruptly creating a domino effect all the way up the line. Down time is extensive, lengthy, and expensive because multiple conveyors need
to be cleared before production can continue.
Solution:
Mount a Magnetic Disk and a ZS09R Zero Speed Switch Sensor to the load side of each conveyor. Wire the ZS09R Zero Speed Switch Sensor contacts in
series with the PLC "Stop" circuits. When a stoppage occurs on one conveyor, the ZS09R Zero Speed Switch Sensor trips within 1 second, enabling
the PLC "Stop" circuit on all conveyors. Down time and clean up are reduced by confining the problem to a single conveyor.
|